The City of Calgary Land Use Bylaw 1P2007
Top of page
Projections Into Rear Setback Area
338
1
Stairs, air conditioning equipment and window wells may project without limits into any rear setback area.
2
Awnings, balconies, bay windows, canopies, chimneys, decks , eaves, fireplaces, fire escapes, landings, porches, and ramps other than wheelchair ramps may project a maximum of 1.5 metres into any rear setback area.
3
A private garage attached to a building may project without limits into a rear setback area provided it:
b
does not exceed 75.0 square metres in gross floor area for each Dwelling Unit located on the parcel;
4
When an attached private garage has a balcony or deck , the balcony or deck must not be located within 6.0 metres of a rear property line or 1.2 metres of a side property line.