The City of Calgary Land Use Bylaw 1P2007
Top of page
PART 11: CENTRE CITY DISTRICTS
Division 6: Centre City Commercial Corridor District (CC-COR)
Purpose
1179
The Centre City Commercial Corridor District is intended to be characterized by:
d
building location, setback areas, and landscaping that limit the effect of commercial uses on adjoining residential districts;
Permitted Uses
2
The following uses are permitted uses in the Centre City Commercial Corridor District if they are located within existing approved buildings:
3
Unless otherwise stated in subsection 1181(2.1), the following uses are permitted uses in the Centre City Commercial Corridor District if they are located within existing approved buildings and if the public area is 150.0 square metres or less:
Discretionary Uses
1181
1
Uses listed in subsection 1180(2) are discretionary uses if they are located in proposed buildings or proposed additions to existing buildings in the Centre City Commercial Corridor District.
1.1
The following uses are discretionary uses in the Centre City Commercial Corridor District if they are located within existing approved buildings and if the public area is greater than 150.0 square metres:
1.2
The following uses are discretionary uses in the Centre Commercial Corridor District if they are located in proposed buildings or proposed additions to existing buildings:
2.1
The following uses are discretionary uses if they are proposed in an existing building that does not have at least one use listed in this District that has been approved after the parcel was designated as a commercial land use district.
Rules
1182
In addition to the rules in this District, all uses in this District must comply with:
a
the General Rules for Centre City Multi-Residential Land Use Districts referenced in Part 11, Division 4;
Floor Area Ratio
b
3.0, plus the gross floor area of Dwelling Units above the ground floor, up to a maximum floor area ratio of 5.0.
3
The maximum floor area ratio may be increased in accordance with the bonus provisions contained in Part 11, Division 7.
4
Unless otherwise referenced in subsections (1) to (3), where a development provides units with three or more bedrooms in the form of Assisted Living, Dwelling Units, Live Work Units or Multi-Residential Development, the Development Authority may exclude the three or more bedroom units from the gross floor area ratio calculation, up to a maximum of 15 per cent of the total units in the development.
Building Orientation
1185
1
The main public entrance to a building must face the property line shared with a commercial street.
3
Lobbies or entrances for upper floor uses must not occupy more than 20% of the at grade façade facing a street. For laneless parcels, portions of façades dedicated to underground parking and loading entrances must not be included as part of the at grade façade for the purposes of this rule.
4
For laned parcels, no motor vehicle access, motor vehicle parking stalls, loading stalls, garbage facilities, parkade access/egress or parkade venting may be located between the street and an at grade use.
Building Façade
1186
1
The length of the building façade that faces the commercial street must be a minimum of 80.0 per cent of the length of the property line it faces.
2
In calculating the length of the building façade, the depth of any required rear or side setback area referenced in sections 1191 and 1192 will not be included as part of the length of the property line.
Vehicle Access
2
Where the corner parcel shares a property line with a lane, those parcels may have vehicle access from either the lane or the street.
Use Area
1188
1
Unless otherwise referenced in subsection (3), the maximum use area for uses on the ground floor of buildings in the Centre City Commercial Corridor District is 465.0 square metres.
a
Catering Service — Minor, or a Catering Service — Minor combined with any other use, is 300.0 square metres;
3.1
The maximum public area for a Restaurant: Food Service Only or Restaurant: Licensed is 300.0 square metres.
a
may be located on the same floor as Addiction Treatment, Assisted Living, Custodial Care, Dwelling Units, and Residential Care; and
b
must not share an internal hallway with Addiction Treatment, Assisted Living, Custodial Care, Dwelling Units, and Residential Care.
3
Where this section refers to "Commercial Uses", it refers to the listed permitted and discretionary uses of this District, other than Addiction Treatment, Assisted Living, Custodial Care, Dwelling Units, Home Occupation — Class 1, Home Occupation — Class 2, Multi-Residential Development, Hotel, Place of Worship — Small, and Residential Care.
Front Setback Area
1190
1
The front setback area has no minimum depth requirement and must have a maximum depth of 3.0 metres for parcels located on the following streets:
2
The front setback area must have a minimum depth of 1.5 metres and a maximum depth of 3.0 metres for parcels located on the following streets:
3
The front setback area must have a minimum depth of 1.5 metres and a maximum depth of 6.0 metres for parcels located on the following streets:
4
The front setback area must have a minimum depth of 3.0 metres and a maximum depth of 6.0 metres for parcels located on the following streets:
Rear Setback Area
b
a lane that separates the parcel from a parcel designated as a residential district, the rear setback area must have a minimum depth of 3.0 metres;
Side Setback Area
b
a lane that separates the parcel from a parcel designated as a residential district, the side setback area must have a minimum depth of 3.0 metres;
Floor Plate Restrictions
1193
Each floor located partially or wholly above 36.0 metres above grade, and containing Dwelling Units, Hotel suites or Live Work Units, has a maximum:
Landscaping In Setback Areas
1194
1
Where a setback area shares a property line with a street, the setback area must be a hard surfaced landscaped area.
2
Where a setback area shares a property line with a lane and approved access to the parcel is from the lane, there is no requirement for soft surfaced landscaped area or hard surfaced landscaped area for that setback area.
3
Where a setback area shares a property line with an LRT corridor or a parcel designated as a residential district, the setback area must:
4
Where a setback area shares a property line with a parcel designated as a commercial, industrial or special purpose district, the setback area:
5
Where a setback area shares a property line with a lane that separates the parcel from a parcel designated as a residential district and there is no access from the lane, the setback area:
Parking
1194.1
The minimum number of required motor vehicle parking stalls, visitor parking stalls, bicycle parking stalls — class 1 and bicycle parking stalls — class 2 is the requirement specified in the General Rules for Centre City Commercial Land Use Districts referenced in Part 11, Division 4.